Description
POWER CPS: the high power CPSS also available in the three-phase version
Power range: 6 – 100 kVA
POWER CPS is the UPS specifically designed to guarantee the power supply of emergency devices, capable of reaching a maximum power of 100 kVA.
The system meets all the requirements of the EN-50171 and EN-62040 standards ensuring the highest performance available today in the CPSS sector.
The best CPSS solution for emergency uses up to 100 kVA
POWER CPS is specifically designed for emergency uses, such as lighting systems, fire prevention systems and smoke detection equipment.
This UPS is the best solution on the CPSS market, available in both single-phase and three-phase versions and capable of reaching a maximum power of 100 kVA.
High performance
POWER CPS can support emergency devices up to a maximum power of 100 kVA and can achieve an efficiency of up to 96% in Normal Mode.
The UPS also features cutting-edge components such as the standard supply double input, rectifier and IGBT inverter.
Optimised battery management
The batteries installed inside a CPS system are of fundamental importance in ensuring its operation in emergency conditions.
Indeed, the EN50171 standard lays down specific requirements for batteries installed in a CPS system, such as fast charging to 80% in 12 hours and the use of long-life batteries with an average expected life of 10 years. All these parameters form the basis of the design of POWER CPS, which complies fully with every specific provision laid down by the regulations for Central Power Supply Systems.
The UPS also features an advanced battery management system that allows you to adapt the charging voltage according to the temperature, thus preventing the overheating and overloading of the batteries. The expected life of the batteries is thus extended and charging times are optimised.
Smart maintenance
POWER CPS has a standard supply double input. This important function ensures easier and safer maintenance of the UPS as well as allowing the use of two different power sources.
It is, in fact, possible to perform periodic checks using a specific input switch which interrupts the system power supply whilst leaving the bypass line active.
The UPS also has protection against polarity inversion, thus ensuring maximum safety during maintenance operations.
Best overload capacity
The system features a large power reserve, in fact, as required by the EN50171 standard, the POWER CPS range is designed and sized to permanently manage an overload at 120% of the rated power.